7/16 DIN Male RingFlare™ Connector for 1/2 in LDF4-50A cable

 
  
General Specifications  
Interface   7-16 DIN Male
Body Style   Straight
Brand   HELIAX®   |   RingFlare™
Mounting Angle   Straight
   
Electrical Specifications  
Connector Impedance   50 ohm
Operating Frequency Band   0 – 8800 MHz
Cable Impedance   50 ohm
3rd Order IMD, typical   -120 dBm @ 910 MHz
3rd Order IMD Test Method   Two +43 dBm carriers
RF Operating Voltage, maximum (vrms)   1415.00 V
dc Test Voltage   2000 V
Outer Contact Resistance, maximum   1.50 mOhm
Inner Contact Resistance, maximum   0.80 mOhm
Insulation Resistance, minimum   5000 MOhm
Average Power   1.1 kW @ 900 MHz
Peak Power, maximum   40.00 kW
Insertion Loss, typical  0.05 dB
Shielding Effectiveness   -110 dB
   
   
Mechanical Specifications  
Outer Contact Attachment Method   Ring-flare
Inner Contact Attachment Method   Captivated
Outer Contact Plating   Trimetal
Inner Contact Plating   Silver
Attachment Durability   25 cycles
Interface Durability   500 cycles
Interface Durability Method   IEC 61169-4:9.5
Connector Retention Tensile Force   890 N   |   200 lbf
Connector Retention Torque   5.42 N-m   |   48.00 in lb
Insertion Force   200.17 N   |   45.00 lbf
Insertion Force Method   IEC 61169-1:15.2.4
Pressurizable   No
Coupling Nut Proof Torque   25.00 N-m   |   221.27 in lb
Coupling Nut Retention Force   1000.00 N   |   224.81 lbf
Coupling Nut Retention Force Method   MIL-C-39012C-3.25, 4.6.22
   
Dimensions  
Nominal Size   1/2 in
Diameter   35.56 mm   |   1.40 in
Length   67.01 mm   |   2.64 in
Weight   180.00 g   |   0.40 lb
   
Environmental Specifications  
Operating Temperature   -55 °C to +85 °C (-67 °F to +185 °F)
Storage Temperature   -55 °C to +85 °C (-67 °F to +185 °F)
Immersion Depth  1 m
Immersion Test Mating   Mated
Immersion Test Method   IEC 60529:2001, IP68
Water Jetting Test Mating   Mated
Water Jetting Test Method   IEC 60529:2001, IP66
Moisture Resistance Test Method   MIL-STD-202F, Method 106F
Mechanical Shock Test Method   MIL-STD-202, Method 213, Test Condition I
Thermal Shock Test Method   MIL-STD-202, Method 107, Test Condition A-1, Low Temperature -55 °C
Vibration Test Method   MIL-STD-202F, Method 204D, Test Condition B
Corrosion Test Method   MIL-STD-1344A, Method 1001.1, Test Condition A
   
Standard Conditions  
Attenuation, Ambient Temperature   20 °C   |   68 °F
Average Power, Ambient Temperature   40 °C   |   104 °F

Return Loss/VSWR
Frequency Band VSWR Return Loss (dB)
0–1600 MHz 1.02 39.00
1600–2000 MHz 1.03 36.00
2000–4000 MHz 1.05 33.00
4000–6000 MHz 1.07 30.00
6000–7000 MHz 1.12 25.00
7000–8000 MHz 1.15 23.00
8000–8800 MHz 1.2 21.00

Kabel heliax andrew ldf4 ldf5 dan berbagai jenis konektor kabel dan juga grounding kit serta arrester merk andrew

Untuk mendapatkan penawaran harga silahkan hubungi sales kami di:

Email : info@radiokomunikasi.com
Telp : (021) 4211456 - 4211477
WA : 0812 8191 7839
WA : 0811 1477 192
WA : 0811 1477 195
WA : 0811 9048 889
No reviews

Mungkin anda suka

10 produk lainnya dikategori yang sama:

Product added to wishlist
Product added to compare.